name: "mdr-745-specialist" description: EU MDR 2017/745 compliance specialist for medical device classification, technical documentation, clinical evidence, and post-market surveillance. Covers Annex VIII classification rules, Annex II/III technical files, Annex XIV clinical evaluation, Art. 86 PSUR schedules, and EUDAMED integration. Use when classifying a medical device under MDR, building or gap-checking a technical file, planning clinical evaluation or PMS/PSUR cadence, or preparing for notified body review (e.g., 'what class is my device under MDR', 'review my PSUR schedule'). triggers:
- MDR compliance
- EU MDR
- medical device classification
- Annex VIII
- technical documentation
- clinical evaluation
- PMCF
- EUDAMED
- UDI
- notified body
MDR 2017/745 Specialist
EU MDR compliance patterns for medical device classification, technical documentation, and clinical evidence.
Table of Contents
- Device Classification Workflow
- Technical Documentation
- Clinical Evidence
- Post-Market Surveillance
- EUDAMED and UDI
- Reference Documentation
- Tools
Device Classification Workflow
Classify device under MDR Annex VIII:
- Identify device duration (transient, short-term, long-term)
- Determine invasiveness level (non-invasive, body orifice, surgical)
- Assess body system contact (CNS, cardiac, other)
- Check if active device (energy dependent)
- Apply classification rules 1-22
- For software, apply MDCG 2019-11 algorithm
- Document classification rationale
- Validation: Classification confirmed with Notified Body
Classification Matrix
| Factor | Class I | Class IIa | Class IIb | Class III |
|---|---|---|---|---|
| Duration | Any | Short-term | Long-term | Long-term |
| Invasiveness | Non-invasive | Body orifice | Surgical | Implantable |
| System | Any | Non-critical | Critical organs | CNS/cardiac |
| Risk | Lowest | Low-medium | Medium-high | Highest |
Software Classification (MDCG 2019-11)
| Information Use | Condition Severity | Class |
|---|---|---|
| Informs decision | Non-serious | IIa |
| Informs decision | Serious | IIb |
| Drives/treats | Critical | III |
Classification Examples
Example 1: Absorbable Surgical Suture
- Rule 8 (implantable, long-term)
- Duration: > 30 days (absorbed)
- Contact: General tissue
- Classification: Class IIb
Example 2: AI Diagnostic Software
- Rule 11 + MDCG 2019-11
- Function: Diagnoses serious condition
- Classification: Class IIb
Example 3: Cardiac Pacemaker
- Rule 8 (implantable)
- Contact: Central circulatory system
- Classification: Class III
Technical Documentation
Prepare technical file per Annex II and III:
- Create device description (variants, accessories, intended purpose)
- Develop labeling (Article 13 requirements, IFU)
- Document design and manufacturing process
- Complete GSPR compliance matrix
- Prepare benefit-risk analysis
- Compile verification and validation evidence
- Integrate risk management file (ISO 14971)
- Validation: Technical file reviewed for completeness
Technical File Structure
ANNEX II TECHNICAL DOCUMENTATION
├── Device description and UDI-DI
├── Label and instructions for use
├── Design and manufacturing info
├── GSPR compliance matrix
├── Benefit-risk analysis
├── Verification and validation
└── Clinical evaluation report
GSPR Compliance Checklist
| Requirement | Evidence | Status |
|---|---|---|
| Safe design (GSPR 1-3) | Risk management file | ☐ |
| Chemical properties (GSPR 10.1) | Biocompatibility report | ☐ |
| Infection risk (GSPR 10.2) | Sterilization validation | ☐ |
| Software requirements (GSPR 17) | IEC 62304 documentation | ☐ |
| Labeling (GSPR 23) | Label artwork, IFU | ☐ |
Conformity Assessment Routes
| Class | Route | NB Involvement |
|---|---|---|
| I | Annex II self-declaration | None |
| Is/Im | Annex II + IX/XI | Sterile/measuring aspects |
| IIa | Annex II + IX or XI | Product or QMS |
| IIb | Annex IX, or Annex X + XI | QMS + tech doc assessment, or type exam + production |
| III | Annex IX, or Annex X + XI | Full QMS + product dossier, or type exam + production |
Clinical Evidence
Develop clinical evidence strategy per Annex XIV:
- Define clinical claims and endpoints
- Conduct systematic literature search
- Appraise clinical data quality
- Assess equivalence (technical, biological, clinical)
- Identify evidence gaps
- Determine if clinical investigation required
- Prepare Clinical Evaluation Report (CER)
- Validation: CER reviewed by qualified evaluator
Evidence Requirements by Class
| Class | Minimum Evidence | Investigation |
|---|---|---|
| I | Risk-benefit analysis | Not typically required |
| IIa | Literature + post-market | May be required |
| IIb | Systematic literature review | Often required |
| III | Comprehensive clinical data | Required (Article 61) |
Clinical Evaluation Report Structure
CER CONTENTS
├── Executive summary
├── Device scope and intended purpose
├── Clinical background (state of the art)
├── Literature search methodology
├── Data appraisal and analysis
├── Safety and performance conclusions
├── Benefit-risk determination
└── PMCF plan summary
Qualified Evaluator Requirements
- Medical degree or equivalent healthcare qualification
- 4+ years clinical experience in relevant field
- Training in clinical evaluation methodology
- Understanding of MDR requirements
Post-Market Surveillance
Establish PMS system per Chapter VII:
- Develop PMS plan (Article 84)
- Define data collection methods
- Establish complaint handling procedures
- Create vigilance reporting process
- Plan Periodic Safety Update Reports (PSUR)
- Integrate with PMCF activities
- Define trend analysis and signal detection
- Validation: PMS system audited annually
PMS System Components
| Component | Requirement | Frequency |
|---|---|---|
| PMS Plan | Article 84 | Maintain current |
| PSUR | Article 86 — Class IIa and higher | Per Art. 86(1) schedule below |
| PMCF Plan | Annex XIV Part B | Update with CER |
| PMCF Report | Annex XIV Part B | Annual (Class III) |
| Vigilance | Articles 87-92 | As events occur |
PSUR Schedule
| Class | Frequency (MDR Art. 86(1)) |
|---|---|
| Class III | Updated at least annually |
| Class IIb (all, incl. implantable) | Updated at least annually |
| Class IIa | When necessary, at least every 2 years |
| Class I | No PSUR — PMS report instead (Art. 85) |
Serious Incident Reporting
| Timeline | Requirement |
|---|---|
| 2 days | Serious public health threat |
| 10 days | Death or serious deterioration |
| 15 days | Other serious incidents |
EUDAMED and UDI
Implement UDI system per Article 27:
- Obtain issuing entity code (GS1, HIBCC, ICCBBA)
- Assign UDI-DI to each device variant
- Assign UDI-PI (production identifier)
- Apply UDI carrier to labels (AIDC + HRI)
- Register actor in EUDAMED
- Register devices in EUDAMED
- Upload certificates when available
- Validation: UDI verified on sample labels
EUDAMED Modules
| Module | Content | Actor |
|---|---|---|
| Actor | Company registration | Manufacturer, AR |
| UDI/Device | Device and variant data | Manufacturer |
| Certificates | NB certificates | Notified Body |
| Clinical Investigation | Study registration | Sponsor |
| Vigilance | Incident reports | Manufacturer |
| Market Surveillance | Authority actions | Competent Authority |
UDI Label Requirements
Required elements per Article 13:
- UDI-DI (device identifier)
- UDI-PI (production identifier) for Class II+
- AIDC format (barcode/RFID)
- HRI format (human-readable)
- Manufacturer name and address
- Lot/serial number
- Expiration date (if applicable)
Reference Documentation
MDR Classification Guide
references/mdr-classification-guide.md contains:
- Complete Annex VIII classification rules (Rules 1-22)
- Software classification per MDCG 2019-11
- Worked classification examples
- Conformity assessment route selection
Clinical Evidence Requirements
references/clinical-evidence-requirements.md contains:
- Clinical evidence framework and hierarchy
- Literature search methodology
- Clinical Evaluation Report structure
- PMCF plan and evaluation report guidance
Technical Documentation Templates
references/technical-documentation-templates.md contains:
- Annex II and III content requirements
- Design History File structure
- GSPR compliance matrix template
- Declaration of Conformity template
- Notified Body submission checklist
Tools
MDR Gap Analyzer
# Quick gap analysis
python scripts/mdr_gap_analyzer.py --device "Device Name" --class IIa
# JSON output for integration
python scripts/mdr_gap_analyzer.py --device "Device Name" --class III --output json
# Interactive assessment
python scripts/mdr_gap_analyzer.py --interactive
Analyzes device against MDR requirements, identifies compliance gaps, generates prioritized recommendations.
Output includes:
- Requirements checklist by category
- Gap identification with priorities
- Critical gap highlighting
- Compliance roadmap recommendations
Notified Body Interface
Selection Criteria
| Factor | Considerations |
|---|---|
| Designation scope | Covers your device type |
| Capacity | Timeline for initial audit |
| Geographic reach | Markets you need to access |
| Technical expertise | Experience with your technology |
| Fee structure | Transparency, predictability |
Pre-Submission Checklist
- Technical documentation complete
- GSPR matrix fully addressed
- Risk management file current
- Clinical evaluation report complete
- QMS (ISO 13485) certified
- Labeling and IFU finalized
- Validation: Internal gap assessment complete
Related skills
More from alirezarezvani/claude-skills and the wider catalog.
marketing-skills
Directory and router for the marketing skills library. Use when you need to find the right marketing skill for a task, see what marketing capabilities exist, or get oriented in this plugin. 44 specialist skills across 8 pods (content, SEO + AEO, CRO, channels, growth, intelligence, sales enablement, ops), 59 stdlib Python tools. Routes to one skill — it does not execute marketing work itself.
engineering-skills
Index of the engineering-team skills bundle for Claude Code, Codex, Gemini CLI, Cursor, OpenClaw, and 6 more tools. Architecture, frontend, backend, QA, DevOps, security, AI/ML, data engineering, Playwright, Stripe, AWS, MS365 (stdlib-only Python tools). Use when browsing or choosing among engineering-team role skills — load only the one specialist SKILL.md you need, never bulk-load the bundle.
finance-skills
Router/index for the 2 finance skills bundled in this plugin: financial-analyst (ratio analysis, DCF valuation, budget variance, rolling forecasts) and saas-metrics-coach (ARR/MRR, churn, CAC/LTV, NRR, quick ratio). Use when a finance request doesn't obviously match one skill and you need to pick the right one (e.g., 'analyze these financials', 'how healthy are my SaaS metrics').
business-growth-skills
Router/index for the 4 business & growth skills bundled in this plugin: customer-success-manager (health scoring, churn risk, expansion), sales-engineer (RFP analysis, competitive matrices, PoC planning), revenue-operations (pipeline, forecast accuracy, GTM efficiency), and contract-and-proposal-writer. Use when a growth/revenue request doesn't obviously match one skill and you need to pick the right one (e.g., 'which accounts are at risk', 'should we bid on this RFP').
engineering-advanced-skills
Index of 37 advanced engineering agent skills for Claude Code, Codex, Gemini CLI, Cursor, OpenClaw. Use when browsing or choosing among the POWERFUL-tier engineering skills: agent design, RAG, MCP servers, CI/CD, database design, observability, security auditing, changelog/release automation, reliability (SLO/chaos/flags/operators), platform ops.
product-skills
Router/index for the 12 product skills bundled in this plugin (RICE prioritization, OKRs, UX research, design tokens, competitive teardown, analytics, experiments, discovery, roadmaps, spec-to-repo, landing pages, SaaS scaffolding). Use when a product request doesn't obviously match one skill and you need to pick the right one (e.g., 'help me prioritize features', 'plan a product experiment').